SAFETY TRANSFORMERS

Single Phase Safety Transformer

220 / 277 / 380 / 480VAC -

12 / 24VAC

Details

PRIMARY VOLTAGE: 220 / 277 / 380 / 480VAC
SECONDARY VOLTAGE: 12 / 24VAC
STANDARD: In accordance with EN-61558-2-6
ISOLATION CLASS: T40/F
DIELECTRIC STRENGTH:
4600V (between primary and secondary)
3500V (between primary and mass)

PROTECTION DEGREE: IP00
FREQUENCIES: 50 / 60Hz
CONNECTION: Screw faston terminals
FIXINGS: Using angles DIN 41307
WINDING: Enamelled copper wire class H. Separated primary and secondary (galvanic separation)

Safety transformers are intended to supply electric devices where a circuit separation is required. Protected against humidity by means of resin impregnation

Code: 

SPECIFICATIONS

TECHNICAL FEATURES

Power (KVA)CodeDimension ADimension BDimension CDimension DDimension HDimension MxNWeight (Kg)Packing
40TS090404000841009064559x4,81.612
63TS090634000841029064609x4,81.712
100TS09110400096105100846411x5,82.48
160TS09116400096110100847011x5,82.88
200TS09120400096114100847411x5,838
250TS091254000120104120906911x5,84.14
315TS091324000120115120907811x5,84.64
400TS091404000120125120908811x5,85.54
500TS091504000120144126909811x5,86.52
630TS0916340001501201471228413x78.12
800TS09180400015013518212210413x79.82
1000TS09210400015014518312211413x712.61
1600TS09216400015016518212213413x715.81
2000TS09220400019514217715011018x1019.11

DOWNLOADABLE

Documents

Descargar ficha técnica

Descargar Plano

Descargar catálogo

Download catalogue

Mercados suministrados

Sectors


Renewable energy


Industry

SAFETY TRANSFORMERSTS SERIES

SAFETY TRANSFORMERSTS SERIES

Other products

WE MEET YOUR NEEDS

Tailor-made products

If you cannot find what you are looking for, our Technical Department shall look into each project and provide immediate support and personalized service.